Cell Culture Application Hypoxic Workstations

 

Hypoxic Workstations

ตู้ปฏิบัติงานและควบคุมสภาวะสำหรับงานเพาะเลี้ยงเซลล์
Micro environment. Major research.
  • Built-in rapid airlock allows items to be transferred into the workstation atmosphere in 20 seconds and the doors are interlocked so cannot be opened simultaneously.
  • Colour, touchscreen control panel for ease of use and for visual display of parameters such as oxygen level, carbon dioxide level, temperature, humidity, and airlock cycle status.
  • Low gas
  • Fully integrated gas control avoids bulky add-on systems and reduces the need for additional bench space.
  • Optional 15 cm single plate entry system fitted to the side of the workstation.
  • Optional data download facility and oxygen profiling.
  • Can be fitted with a range of cable glands and other options to tailor the workstation to your requirements.
Create hypoxic conditions within a controlled and sustained workstation environment.
  • This cell culture incubator is available with removable front to facilitate thorough cleaning and the transfer of bulk samples or larger pieces of equipment for use in the workstation.
  • Built-in rapid airlock to ensure samples can be transferred into the workstation atmosphere as soon as possible (only takes 60 seconds).
  • Colour, touchscreen control panel for ease of use and for visual display of parameters such as oxygen level, carbon dioxide level, temperature, humidity, and airlock cycle status.
  • Available with fully automatic humidification system so you can add moisture and maintain a sterile environment.
  • Fully integrated gas control avoids bulky add-on systems and reduces the need for additional bench space.
A hypoxic workstation with a third port for instant access.
  • Three portholes provide convenient access to the entire incubation and working areas of the chamber.
  • The removable front facilitates thorough cleaning and the transfer of bulk samples or larger pieces of equipment for use in the workstation.
  • Built-in rapid airlock to ensure samples can be transferred into the workstation atmosphere as soon as possible (only takes 60 seconds).
  • Colour, touchscreen control panel for ease of use and for visual display of parameters such as O2 level, CO2 level, temperature, humidity and airlock cycle status.
  • Ethernet-enabled for remote access to touchscreen.
  • Available with fully automatic humidification system so you can add moisture AND maintain a sterile environment.
  • Fully integrated gas control avoids bulky add-on systems and reduces the need for additional bench space.
Hypoxystation with two airlocks, ideal for two people working side by side.
  • Has a capacity of 600 litres.
  • Removable front as standard on the right-hand half of the unit to facilitate the transfer of bulk samples or larger pieces of equipment for use inside the workstation.
  • The two rapid airlocks can each accommodate up to 4 x 96-well plates or 84 x T25s. The enable items to be withdrawn at either end of the workstation offering maximum flexibility and improving the workflow in your laboratory. Both airlocks can be operated at the same time and take only 60 seconds.
  • Colour, touchscreen control panel for ease of use and for visual display of parameters such as O2 level, CO2 level, temperature, humidity and airlock cycle status.
  • Ethernet-enabled for remote access to touchscreen.
  • Comes complete with custom-designed trolley.
  • Fully integrated gas control avoids bulky add-on systems and reduces the need for additional bench space.
  • Automatic commissioning cycle to save you time and resources.
A Hypoxystation with refrigeration option.
  • Available with patented oval glove ports operated by wireless footswitch to allow you to work gloved or bare handed.
  • Built-in 36 litre airlock for transfer of bulk samples and equipment into the workstation environment.
  • Colour, touch-screen control panel for ease of use and for visual display of parameters such as oxygen level, carbon dioxide level, temperature, humidity, and airlock cycle status.
  • Available with additional options such as HEPA filtration – levels of atmospheric cleanliness inside the workstation exceed the requirements of ISO 14644 Class 3.
  • Fully integrated gas control avoids bulky add-on systems and reduces the need for additional bench space.
  • Reminder to perform calibration can be set for between 7 and 21 days.
A huge, 4-port hypoxic workstation.
  • Fully integrated gas mixing
  • Colour touchscreen interface allows easy monitoring of all parameters simultaneously
  • Ethernet enabled for remote access to touchscreen
  • Multifunctional porthole system – 2 pairs of ports so can be used by 2 users at the same time
  • Each port acts as a mini airlock to transfer small items of lab ware
  • Available with automatic sleeve gassing system
  • Patented oval gloveports to allow bare handed or gloved operation and maximum comfort in use
  • Automated de-humidification as standard
  • Available with the Whitley HEPA Filtration System
  • A wide range of options and accessories to tailor the system to your particular working conditions.
Perfect for accommodating items of laboratory equipment.
  • Precise control of oxygen, carbon dioxide and nitrogen – provides flexibility in your research and confidence in your results.
  • The Whitley Internal HEPA Filtration System with optional Enhanced Biological Containment.
  • A removable front (fitted with two patented oval ports) to facilitate the transfer of large items of equipment for use inside the chamber.
  • Innovative full colour touch screen that is Ethernet-enabled for remote access. Now you can log into your workstation when you are away from the laboratory.
  • Fully automated oxygen calibration routine (Patent No. 3109635) – activated via the touchscreen with no need to touch or remove the sensor – saves time, no risk of user error and ensures the accuracy of your results.
  • Options Include the Whitley Automatic Humidifier – sterile, on-demand moisture addition
A massive hypoxic chamber – the largest in the Whitley Workstation range.
  • Precise control of oxygen, carbon dioxide and nitrogen – provides flexibility in your research and confidence in your results.
  • The Whitley Internal HEPA Filtration System with optional Enhanced Biological Containment.
  • Two removable fronts (each fitted with two patented oval ports) facilitate the transfer of large items of equipment for use inside the chamber.
  • Innovative, full colour touch screen that is Ethernet-enabled for remote access. Now you can log into your workstation when you are away from the laboratory.
  • Fully automated oxygen calibration routine (patent pending) – activated via the touchscreen with no need to touch or remove the sensor – saves time, no risk of user error and ensures the accuracy of your results.
  • Other options include double internal power socket, refrigeration, front loading single sample entry system, cable glands and storage trays.