Anaerobic Workstations

Whitley A25 Workstation

The most compact Whitley Workstation yet!

  • Previously unavailable on a workstation of this size, Whitley Workstations are the only workstations to provide automatic early warnings about the status of the anaerobic

atmosphere and catalyst function.

  • With a wide selection of options available, the A25 can fulfil the needs of any laboratory requiring a compact anaerobic workstation.
  • A versatile instrument, the A25 can also be used as a microaerobic workstation by simply connecting the relevant pre-mixed gas.

Whitley A35 Workstation

Our most versatile, popular Anaerobic Workstation.

  • Accommodates up to 600 x 90mm Petri dishes.
  • A colour, touch-screen control panel for ease of use and for visual display of parameters such as temperature, humidity, and airlock cycle status.
  • With the HEPA model, levels of atmospheric cleanliness inside the workstation exceed the requirements of ISO 14644 Class 3. Proof of atmospheric

cleanliness can be provided on request.

  • Available with a removable front to facilitate thorough cleaning and the transfer of bulk samples and larger pieces of equipment for use in the workstation.
  • The built-in rapid airlock ensures samples can be transferred into the workstation atmosphere as soon as possible.
  • Ethernet-enabled for remote access to touchscreen.
  • Includes an automatic commissioning cycle to save you time and resources.

Whitley A45 Workstation

A 3-port workstation with convenient access to the entire incubation area.

  • A colour, touchscreen control panel for ease of use and for visual display of parameters such as temperature, humidity, and airlock cycle

status.

  • Ethernet-enabled for remote access to touchscreen.
  • Optional removable front with instant access or traditional sleeved ports.
  • Available with a mixture of instant access ports and conventional ports to give you the best arrangement for your application
  • Includes an automatic commissioning cycle to save you time and resources.

Whitley A55 Workstation

Two sets of oval ports

  • Accommodates  between 1,000 and 1,400 x 90mm Petri dishes (depending on whether plate  carriers are used and which accessories and system options have been  incorporated).
  • Removable  front as standard on the right hand half of the unit to facilitate the  transfer of bulk samples or larger pieces of equipment for use inside  the workstation.
  • Two  rapid airlocks each have a 40 Petri dish capacity and allow samples to  be introduced and withdrawn at either end of the workstation offering  maximum flexibility and improving the workflow in your laboratory. Both  airlocks can be operated at the same time.
  • Colour,  touchscreen control panel for ease of use and for visual display of  parameters such as temperature, humidity, and airlock cycle status.
  • Ethernet-enabled for remote access to touchscreen.
  • Comes complete with custom-designed trolley.
  • Optional conventional, oval, sleeved ports or a mixture of oval and instant access ports.

Automatic commissioning cycle to save you time and resources.

Whitley A85 Workstation

A fixed front workstation with a huge 30 litre airlock!

  • The airlock, with powered internal door, provides effective sample and equipment transfer in the fastest possible time whilst

ensuring the minimum amount of oxygen is introduced into the chamber.

  • Dual gas operation to minimise running costs or order the TG version to further reduce costs.
  • Includes automatic commissioning cycle to save you time and resources.

Options include HEPA filtration, a refrigeration unit, and an integrated Anaerobic Conditions Monitor with data download facility

Whitley A95 Workstation

A 4 port workstation with a huge 30 litre airlock!

  • Each porthole also acts as a mini-airlock so you can transfer 10 plates through each time you insert or withdraw your arms, so reducing airlock cycles and gas usage.
  • With dual gas operation, this workstation is very cost-effective but a TG (three gas) version can also be specified to further reduce costs.
  • With the HEPA model, levels of atmospheric cleanliness inside the workstation exceed the requirements of ISO 14644 Class 3. Proof of atmospheric cleanliness can be provided on request.
  • Available with fully integrated Anaerobic Conditions Monitor with data download facility.
  • Optional automatic sleeve gassing for cost-effective gas usage and to ensure internal conditions are maintained when entering the chamber.

Whitley A135 HEPA Workstation

A tall, wide, deep anaerobic workstation

  • The built-in rapid airlock ensures samples can be transferred into the workstation atmosphere as soon as possible (takes only 60 seconds).
  • Fitted with a removable front to facilitate thorough cleaning, easy replacement of the HEPA filter, and the transfer of bulk samples and larger pieces of equipment for use in the workstation.
  • Fully integrated gas control avoids bulky add-on systems – reduces the need for additional bench space.
  • A colour, touch-screen control panel for ease of use and for visual display of parameters such as temperature, humidity, and airlock cycle status.
  • Includes an automatic commissioning cycle to save you time and resources.
  • Options include an integrated Anaerobic Conditions Monitor with data download facility.

Whitley A155 HEPA Workstation

A huge, double workstation perfect for accommodating a variety of laboratory equipment

  • Two removable fronts to enable the transfer of larger batches of samples or pieces of equipment for use inside the chamber.
  • Patented oval ports enable you to work comfortably, gloved or bare handed. Each port includes an isolator switch so that you can use one port at a time, if required. The fact that there are two sets of ports means that two researchers can work in the chamber side-by-side.
  • Colour, touch-screen control panel for ease of use and for visual display of parameters such as temperature, humidity, and airlock cycle status.
  • Two new options are available: a rotating turntable (up to 3 per shelf) to hold up to 80 x 90mm Petri dishes; and the movable platform to facilitate the movement of heavy items of equipment inside the chamber.
  • Other options include: double internal power socket, front loading single sample entry system; cable glands, shelves with optional storage trays, Anaerobic Conditions Monitor and data logging.
  • A fully comprehensive maintenance and breakdown contract is also available to prolong the life of your investment. (Note: different arrangements apply in different countries).

เครื่องปรับสภาวะอากาศในโถบ่ม

Whitley Jar Gassing System 

Create the perfect conditions for growing anaerobes in just 2 minutes

  • Reduces the cost of creating microaerobic conditions by 98% and for anaerobic conditions by 89%.
  • It is easy to use so no complicated operator training is required.
  • Incorporates PIN code protected user access levels for additional security.
  • The optional printer enables you to create a hard copy audit trail for accreditation purposes.

โถบ่มเพาะเชื้อ

Anaerobic Jars

Sturdy jars for simple culture of anaerobic and microaerophillic organisms

Two versions are available:

  • a 9 Plate Jar with a 3 litre capacity
  • a 48 Plate Jar with a 10 litre capacity